山西省特殊建设工程消防设计审查要点及规则(高速公路隧道)

山西省特殊建设工程消防设计审查要点及规则(高速公路隧道)

分享会员:甜****百

机电设备: 消防工程

资料介绍

引 言········································································ 1 

1 范围·······································································2 

2 术语·······································································3 

3 一般要求··································································· 4 

4 审查内容··································································· 5 

5 结果判定··································································· 6 

6 档案管理··································································· 7 

附录 A 高速公路隧道消防设计文件审查要点········································· 8

A.1 消防设计文件编制深度···················································8 

A.2 高速公路隧道消防设施配置等级、耐火等级···································8 

A.3 总平面布局和平面布置···················································8 

A.4 防火构造····························································· 8 

A.5 安全疏散设施·························································· 9 

A.6 灭火救援设施·························································· 9 

A.7 消防给水和消防设施···················································· 9 

A.8 隧道防烟与排烟设施··················································· 10 

A.9 消防用电及电气防火··················································· 11 

A.10 交通监控··························································· 12

附录 B 高速公路隧道消防设计文件审查要点细目·····································13

参考文献····································································· 41

1 范 围

本规则适用于山西省建设工程消防设计审查验收主管部门依法对本行政区域内、单洞长度大于500 米单的新建、扩建、改建高速公路隧道的消防设计审查。

消防技术服务机构开展的高速公路隧道消防设计文件技术审查也应按照本规则执行。

2 术 语

2.1 高速公路隧道的消防设计审查

根据《中华人民共和国消防法》《建设工程消防设计审查验收管理暂行规定》《山西省建设工程消 防设计审查验收工作实施细则(试行)》等国家和我省法律法规和工程建设消防技术标准,对单洞长度 大于 500 米高速公路隧道的相关资料和消防设计文件,进行审查、判定并作出行政许可决定的行为。

2.2 资料审查

依据消防法律法规和消防设计审查验收主管部门规定,对建设单位的申报材料是否齐全并符合规定 要求的审查。

2.3 消防设计文件审查

依据消防法律法规、消防设计审查验收主管部门规定和国家及山西省工程建设消防技术标准,对建 设单位申报的特殊建设工程消防设计文件是否符合规定及标准要求的审查。

2.4 综合评定

综合考虑资料审查和消防设计文件审查情况,做出高速公路隧道消防设计审查结论。 2.5 特殊消防设计

指国家工程建设消防技术标准没有规定,必须采用国际标准、境外工程建设消防技术标准的或消防 设计文件拟采用的新技术、新工艺、新材料不符合国家工程建设消防技术标准规定的消防设计。

......